Fixes #3018: Components connected via a cable must have an equal number of positions
This commit is contained in:
parent
ea32853ab3
commit
a32d185ff0
@ -10,6 +10,7 @@ v2.6.2 (FUTURE)
|
|||||||
|
|
||||||
## Bug Fixes
|
## Bug Fixes
|
||||||
|
|
||||||
|
* [#3018](https://github.com/netbox-community/netbox/issues/3018) - Components connected via a cable must have an equal number of positions
|
||||||
* [#3289](https://github.com/netbox-community/netbox/issues/3289) - Prevent position from being nullified when moving a device to a new rack
|
* [#3289](https://github.com/netbox-community/netbox/issues/3289) - Prevent position from being nullified when moving a device to a new rack
|
||||||
* [#3293](https://github.com/netbox-community/netbox/issues/3293) - Enable filtering device components by multiple device IDs
|
* [#3293](https://github.com/netbox-community/netbox/issues/3293) - Enable filtering device components by multiple device IDs
|
||||||
* [#3315](https://github.com/netbox-community/netbox/issues/3315) - Enable filtering devices/interfaces by multiple MAC addresses
|
* [#3315](https://github.com/netbox-community/netbox/issues/3315) - Enable filtering devices/interfaces by multiple MAC addresses
|
||||||
|
@ -2772,6 +2772,16 @@ class Cable(ChangeLoggedModel):
|
|||||||
self.termination_a_type, self.termination_b_type
|
self.termination_a_type, self.termination_b_type
|
||||||
))
|
))
|
||||||
|
|
||||||
|
# A component with multiple positions must be connected to a component with an equal number of positions
|
||||||
|
term_a_positions = getattr(self.termination_a, 'positions', 1)
|
||||||
|
term_b_positions = getattr(self.termination_b, 'positions', 1)
|
||||||
|
if term_a_positions != term_b_positions:
|
||||||
|
raise ValidationError(
|
||||||
|
"{} has {} positions and {} has {}. Both terminations must have the same number of positions.".format(
|
||||||
|
self.termination_a, term_a_positions, self.termination_b, term_b_positions
|
||||||
|
)
|
||||||
|
)
|
||||||
|
|
||||||
# A termination point cannot be connected to itself
|
# A termination point cannot be connected to itself
|
||||||
if self.termination_a == self.termination_b:
|
if self.termination_a == self.termination_b:
|
||||||
raise ValidationError("Cannot connect {} to itself".format(self.termination_a_type))
|
raise ValidationError("Cannot connect {} to itself".format(self.termination_a_type))
|
||||||
|