Fixes #1266: Prevent termination a circuit to an already-connected interface

This commit is contained in:
Jeremy Stretch 2017-06-14 10:57:43 -04:00
parent 16d694734b
commit 78d74261e9

View File

@ -220,7 +220,7 @@ class CircuitTerminationForm(BootstrapMixin, ChainedFieldsMixin, forms.ModelForm
label='Interface',
widget=APISelect(
api_url='/api/dcim/interfaces/?device_id={{device}}&type=physical',
disabled_indicator='is_connected'
disabled_indicator='connection'
)
)