Closes #4218: Allow negative voltage for DC power feeds
This commit is contained in:
19
netbox/dcim/migrations/0099_powerfeed_negative_voltage.py
Normal file
19
netbox/dcim/migrations/0099_powerfeed_negative_voltage.py
Normal file
@@ -0,0 +1,19 @@
|
||||
# Generated by Django 2.2.10 on 2020-03-03 16:59
|
||||
|
||||
from django.db import migrations, models
|
||||
import utilities.validators
|
||||
|
||||
|
||||
class Migration(migrations.Migration):
|
||||
|
||||
dependencies = [
|
||||
('dcim', '0098_devicetype_images'),
|
||||
]
|
||||
|
||||
operations = [
|
||||
migrations.AlterField(
|
||||
model_name='powerfeed',
|
||||
name='voltage',
|
||||
field=models.SmallIntegerField(default=120, validators=[utilities.validators.ExclusionValidator([0])]),
|
||||
),
|
||||
]
|
||||
@@ -24,6 +24,7 @@ from extras.models import ConfigContextModel, CustomFieldModel, ObjectChange, Ta
|
||||
from utilities.fields import ColorField, NaturalOrderingField
|
||||
from utilities.models import ChangeLoggedModel
|
||||
from utilities.utils import serialize_object, to_meters
|
||||
from utilities.validators import ExclusionValidator
|
||||
from .device_component_templates import (
|
||||
ConsolePortTemplate, ConsoleServerPortTemplate, DeviceBayTemplate, FrontPortTemplate, InterfaceTemplate,
|
||||
PowerOutletTemplate, PowerPortTemplate, RearPortTemplate,
|
||||
@@ -1775,9 +1776,9 @@ class PowerFeed(ChangeLoggedModel, CableTermination, CustomFieldModel):
|
||||
choices=PowerFeedPhaseChoices,
|
||||
default=PowerFeedPhaseChoices.PHASE_SINGLE
|
||||
)
|
||||
voltage = models.PositiveSmallIntegerField(
|
||||
validators=[MinValueValidator(1)],
|
||||
default=POWERFEED_VOLTAGE_DEFAULT
|
||||
voltage = models.SmallIntegerField(
|
||||
default=POWERFEED_VOLTAGE_DEFAULT,
|
||||
validators=[ExclusionValidator([0])]
|
||||
)
|
||||
amperage = models.PositiveSmallIntegerField(
|
||||
validators=[MinValueValidator(1)],
|
||||
@@ -1859,10 +1860,16 @@ class PowerFeed(ChangeLoggedModel, CableTermination, CustomFieldModel):
|
||||
self.rack, self.rack.site, self.power_panel, self.power_panel.site
|
||||
))
|
||||
|
||||
# AC voltage cannot be negative
|
||||
if self.voltage < 0 and self.supply == PowerFeedSupplyChoices.SUPPLY_AC:
|
||||
raise ValidationError({
|
||||
"voltage": "Voltage cannot be negative for AC supply"
|
||||
})
|
||||
|
||||
def save(self, *args, **kwargs):
|
||||
|
||||
# Cache the available_power property on the instance
|
||||
kva = self.voltage * self.amperage * (self.max_utilization / 100)
|
||||
kva = abs(self.voltage) * self.amperage * (self.max_utilization / 100)
|
||||
if self.phase == PowerFeedPhaseChoices.PHASE_3PHASE:
|
||||
self.available_power = round(kva * 1.732)
|
||||
else:
|
||||
|
||||
Reference in New Issue